SIGNALDAFP SCRIPT



The SignalDAFP script is designed for measuring the duration, amplitude, frequency and duty cycle of the signal.

This script is necessary when checking signals such as an air flow sensor with a digital signal, a control signal for solenoid valves, injectors, PWM sensors, etc..

This test allows you to display signal parameters:

  • Frequency. Display signals with a variable frequency, for example, an air flow sensor HFM6
  • PWM (Pulse-width modulation). Display signals with a variable duty cycle, for example, the air temperature signal from the HFM6 sensor
  • Duration. Display signals with variable duration pulses, for example, a fuel injector control pulse
  • Amplitude. Display analog signals, for example, the throttle potentiometer signal

To run the script, call the menu:

  • Analysis => Open script => SignalDAFP.ajs
  • Analysis => Execute script

Waveform examples


The USB Oscilloscope program is required for waveform playback
Script SignalDAFP v1.08 - last version
Bosch HFM6 output signal

CSS, PX, ELPOWER, SIGNALDAFP SCRIPTS

Bosch HFM5 / HFM6 Testing using SignalDAFP script